H2 Electric Parts Test

This is test method of individual electric parts. Do all test at room temperature. In the following tests using an ohmmeter, some meters will have to be connected in reverse to obtain the correct readings. "+" and "-" indicate the positive and negative meter leads, respectively. All resistance readings in ohms are approximate. If meter readings do not correspond to the valves given, the part can be considered defective.

1. Ignition Unit

Igunition unit

Step 1. Check resistance between the Black and Light Green wires using the Rx10 range of the ohmmeter.

Connect to + Connect to - R x 10 = Value
Black Light Green ∞ (no reading)
Light Green Black ∞ (no reading)

Step 2. Check resistance between the Light Green and Red wires using the Rx100 range of the ohmmeter.

Connect to + Connect to - R x 100 = Value
Black Red For either measurement the meter needle should jump and then return to infinity (no reading).
Red Black

2. Ignition Rectifier Unit

Igunition rectifier unit

Step 1. Measure resistance between the Black-White lead and the Blue, White and Green leads, one at a time, using the Rx10 ohmmeter range.

Connect to + Connect to - R x 10 = Value
Black - White Blue I20 ~ 35 Ω
Black - White Green I20 ~ 35 Ω
Black - White White 75 ~ 250 Ω
Blue Black - White ∞ (no reading)
Green Black - White ∞ (no reading)
White Black - White ∞ (no reading)

Step 2. Measure resistance between the Black-White lead and each Light-Green wire in turn, using the Rx10 ohmmeter range.

Connect to + Connect to - R x 10 = Value
Black - White Light Green ∞ (no reading)
Light Green Black - White 25 ~ 250 Ω

3. Regulator

Step 1. Measure resistance between the Black and Red lead using the Rx10 ohmmeter range.

Connect to + Connect to - R x 10 = Value
Black Red 700 ~ 1,000 Ω
Red Black 70 ~ 200 Ω

Step 2. Measure resistance between the Black and Yellow lead using the Rx10 ohmmeter range.

Connect to + Connect to - R x 10 = Value
Black Yellow 1,000 ~ 1,200 Ω
Yellow Black 25 ~ 100 Ω

Step 3. Measure resistance between the Red lead and Yellow lead using the Rx10 ohmmeter range.

Connect to + Connect to - R x 10 = Value
Red Yellow 25 ~ 90 Ω
Yellow Red One Yellow: Under 2K Ω
Other Yellow: Under 6K Ω

Step 4. Connect the battery voltage indicated - to the Black lead and + to the Red lead. Then measure resistance between the two Yellow leads.

16VDC

Connect to + Connect to - 16VDC = Value
Yellow Yellow ∞ (no reading)
Reversed 500 Ω

Less than 14VDC

Connect to + Connect to - 14VDC = Value
Yellow Yellow ∞ (no reading)

4. AC Generator

Step 1. Generator resistance readings should be taken with the generator at normal temperatures, not when it is excessively hot from running.
*A light blue parts are not mentioned in Shop manual.

Connect to + Connect to - R x 10 = Value
Yellow Yellow 0.4 Ω
either Yellow Ground ⊥ ∞ (no reading)
Blue Green 5.0 Ω
White Green 200 Ω
Black each White 200 Ω
Black Stator body ⊥ 0 Ω
Green Ground ⊥ ∞ (no reading)

5. Signal pickup coil

Picup coil

Step 1. Measure resistance between the Black and White

Connect to + Connect to - R x 10 = Value
White Black 200 Ω

6. Ignition coil

Ignision coil

Step 1. Resistance between the White lead and the core.

Connect to + Connect to - R x 10 = Value
White Core ⊥ 0.64 ~ 96 Ω